Waldorf IN8200E-CB 800 Series 450mm Electric Induction Cooktop Cabinet Base

Installation Operation Manual - Page 7

For IN8200E-CB.

PDF File Manual, 21 pages, Read Online | Download pdf file

IN8200E-CB photo
Loading ...
Loading ...
Loading ...
5
Specifications
Electrical Supply Requirements
Electrical Connection
The electrical supply connection point is located at the rear of the appliance, approximately 130 mm
from the right hand side and 48 mm from the rear of the appliance and 614 mm from the floor.
When connecting a this electric appliance to the mains supply, ensure that the following is carried
out:-

An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in
such a position that the user does not have to reach across the cooking surface.
 Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS/NZS
3191 part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
 The branch supply line shall be individually overload protected to the correct current
rating and the supply cord shall be protected against any mechanical or thermal damage.
 A grommet is fitted around the wiring entry hole into the appliance.
 All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance
for the current drawn on that line.
WARNING:
T
HIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.
Model
Power Supply
Total Power
Input
Amps
Voltage Type Frequency
L1 L2 L3
IN8200E
400-415 Vac 3P+E 50 / 60 Hz 10 kW 16 16 16
IN8400E
400-415 Vac 3P+E 50 / 60 Hz 20 kW 32 32 32
Loading ...
Loading ...