5A. 3-Wire Connection
1. Remove the three (3) loose nuts on the terminal block
using a 3/8" nut driver or socket.
NOTE: Do not loosen the nuts which secure the factory
installed range wiring to the terminal block. Electrical
failure or loss of electrical connection may occur if nuts
are loosened.
2. Using the nuts removed in step 1, connect the cable or
copper power supply cord to the three (3) studs on the
terminal block, as local codes require. The neutral
(white) wire or center wire must be connected to the
center terminal.
3. Make sure all nuts are tightened securely.
4. Replace the rear access cover.
GROUNDING INSTRUCTIONS:
A ground link is installed on this range which connects the
center terminal of the terminal block (neutral) to the
chassis. The ground link is not visible in the picture below
but is connected to the range by the center, lowest screw
(shown in picture below). The ground link must not be
removed unless national or local codes do not permit use
of ground link.
NOTE: If the ground link is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis and to an
adequate ground source.
5B. 4-Wire Connection
If connecting to a 4-wire electrical system (mobile home
required):
1. Remove the three (3) loose nuts on the terminal block
using a 3/8" nut driver or socket. From the center stud
on the terminal block, remove the second nut and the
copper ground strap. Replace the nut that held the
ground strap to the terminal block.
NOTE: Do not loosen the second nut on line1 or line
2 which secure the factory installed range wiring to the
terminal block. Electrical failure or loss of electrical
connection may occur if nuts are loosened.
2. Remove the ground screw to release the copper ground
strap from the appliance.
3. Discard the ground strap. Connect the ground wire
(green) of the copper power supply cord to the frame
of the appliance with the ground screw, using the same
hole in the frame where the ground strap was removed.
4. Using the nuts removed in step 1, connect the neutral
(white) wire of the copper power supply cord to the
center silver colored stud on the terminal block.
5. Connect the final two (2) wires to the outer studs on
the terminal block.
6. Make sure all nuts are tightened securely.
7. Replace the rear access cover.
\
3-Wire Copper Power Supply Cord (40 Amperes).
To Fused Disconnect Box or Approved
Wiring Device for Copper Supply Cord.
Terminal
Terminal
No. 8 Green
Insulated
Copper
Ground
Wire
4=Wire Copper Power Supply Cord (40 Amperes).
To Fused Disconnect Box or Approved
Wiring Device for Copper Supply Cord,
Loading ...