— 9 —
Important Safety Information
INSTALLATION WARNINGS
To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that
the materials used will not discolor, delaminate or
sustain other damage. This oven has been designed
in accordance with the requirements of UL and CSA
International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
MOBILE HOME – ADDITIONAL INSTALLATION
REQUIREMENTS:
The installation of this range must conform to the

Title 24 CFR, Part 3280 (formerly the Federal Standard

Part 280).
When such standard is not applicable, use the Standard

501A or with local codes.
In Canada, the installation of this range must conform

edition, or with local codes.
MOBILE HOME INSTALLATIONS REQUIRE:
When this range is installed in a mobile home, it must

securing the range is adequate as long as it conforms to
the standards listed above.
GAS DANGER
Explosion hazard conditions will exist unless
you perform ALL of the following:

supply line.



gas pressure does not exceed 14” (36 cm) water column.

- Licensed heating personnel
- Authorized gas company personnel
- Authorized service personnel
Failure to do so can result in death, explosion, or re.

IMPORTANT: This installation must conform with all
local codes and ordinances. In the absence of local
codes, installation must conform with American National
Standard, National Fuel Gas Code ANSI Z223.1 - latest

IMPORTANT: Leak testing of the range must be


range location. A smaller size pipe on longer runs may
result in insufcient gas supply. Pipe-joint compounds
that resist the action of LP gas must be used. Do not use
TEFLON® tape. With LP gas, piping or tubing size must

determine the size and materials used in the system.

appliance and be a minimum of 1” from the back wall
(See Figure 2):
Types of Gas
NATURAL GAS:

proper conversion, for use with LP gas.


of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local
gas supplier.
LP GAS CONVERSION:
Conversion must be done by a qualied service technician.


use with a different gas without consulting the serving
gas supplier.