29
I. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
• If the icemaker is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
The pump motor is energized continuously when the control switch is in the
"SERVICE" position.
At startup, conrm that all internal and external connections are free of leaks.
Additional Notice for Remote Models
The icemaker must have power for a minimum of 4hours prior to startup to
prevent compressor damage.
1) Open the water supply line shut-off valve(s).
2) Remove the front panel.
3) Move the control switch to the "ICE" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply and allow the icemaker to operate for a total of 10 minutes.
6) Remove the front panel, then move the service switch to the "DRAIN" position.
7) Replace the front panel in its correct position and allow the icemaker to drain for
2 minutes.
8) Turn off the power supply.
9) Remove the front panel, then move the control switch to the "ICE" position. Replace the
front panel in its correct position.
10) Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
11) Turn on the power supply to start the automatic icemaking process.
12) During the rst 5 minutes of the freeze cycle, conrm bin control operation by pressing
and holding the bin control's actuator paddle until the icemaker shuts down. The
icemaker should shut down in approximately 15 seconds.
13) On water-cooled models, conrm proper condenser drain outlet/return outlet
temperature as outlined in "II.F.2. Water-Cooled Condenser."