Hoshizaki KMD530MWJ KMD-530MWJ 30" Water Cooled Modular Crescent Cuber with 515 lbs. Daily Ice Production, EverCheck Alert System, CycleSaver Design and H-GUARD Plus Antimicrobial Agent in Stainless Steel

Instruction Manual - Page 19

For KMD530MWJ.

PDF File Manual, 38 pages, Read Online | Download pdf file

KMD530MWJ photo
Loading ...
Loading ...
Loading ...
19
2. Water-Cooled Condenser
a) Connection to an Open Drain System
Condenser Water
Supply Inlet
Minimum Condenser
Water Supply Line Size
Condenser Drain
Outlet
Minimum Condenser
Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID Copper
Water Tubing or Equivalent
3/8" Female Pipe
Thread (FPT)
1/4" Nominal ID Hard Pipe
or Equivalent
A condenser water supply line shut-off valve and drain valve must be installed.
• In some areas, a back ow preventer may be required in the cooling water circuit.
• In order to maintain the proper high side pressure, the condenser water supply inlet
temperature should not drop below 45°F (7°C) and the condenser drain outlet temperature
must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation
is complete, conrm the condenser drain outlet temperature 5 minutes after a freeze
cycle starts. If the condenser drain outlet temperature is not in the proper range, use a
at blade screwdriver to rotate the adjustment screw on the water-regulating valve until
the temperature is in the proper range (rotate counterclockwise to raise temperature or
clockwise to lower temperature).
Fig. 9
Water-Cooled Models
Connection to an Open Drain System
Icemaker
Icemaker Water
Supply Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
Floor
Drain
Icemaker
Drain Outlet
3/4" FPT
Condenser Water
Supply Inlet
1/2" FPT
Condenser
Drain Outlet
3/8" FPT
Model Shown:
KMD-460MWJ
Vent Tube
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Vent Tube
Ice
Storage
Bin
Minimum 1/4"
Nominal ID Hard
Pipe or Equivalent
Separate piping to approved
drain. Leave a 2" (5-cm)
vertical air gap between the
end of each pipe and the
drain.
Be sure there is sufficient
extra water supply line and
drain line for the appliance
to be pulled out for service.
Drain Valve
Shut-Off Valve
Minimum 1/4" Nominal ID Copper
Water Tubing or Equivalent
2" (5-cm) air gap
Loading ...
Loading ...
Loading ...