MOD. BEZZERA MATRIX-DUO
Warnings:
- A safety device will interrupt the operation of
the motor pump after 120 seconds if the mini-
mum level of water in the boiler is not reached.
The machine will signal this alarm via pop-up
blocking operation of the machine.
- To restart supply and to resolve the error it is
necessary to switch it off and on again with the
main switch (fig 3 pos1).
5.4 Coffee preparation
1) Disconnect the filter-holder (Fig. 03; pos. 7)
from the group head.
2) Load the filter-holder with ground coffee, press
the coffee taking care not to get the edge of
the filter-holder dirty.
3) Start dispensing without a filter-holder for
approximately 2/3 seconds max. (GROUP
FLUSH).
4) Insert the filter-holder in the group head.
5) Raise the lever to the horizontal position (MN)
or press one of the dispensing buttons (DE) to
obtain coffee dispensing.
6) MN version: To stop dispensing, when
the desired dose is reached, return the lever
(Fig.03, Pos.02) to the vertical position, to al-
low the group to drain and the coffee panel to
dry.
7) DE Version: Dispensing stops at the end of
the programmed dose (Fig.05) unless the con-
tinuous dispensing button is pressed, in which
case the dispensing should be interrupted
when the desired quantity of coffee is reached,
by pressing the continuous dose button again.
Warning:
- Do not remove the filter-holder when the ma-
chine is operating.
- Do not directly touch the metal part of the filter-
holder: risk of burns.
- The standard doses for the filters are 8 grams
for one dose and 16 grams for two doses.
5.4.1 Coffee settings
From the home screen, it is possible to access the
coffee settings screen by simply tapping the coffee
temperature value shown on the screen.
In this screen it is possible to choose the coffee
infusion water temperature optimised according
to the SCAE protocols in a range from + 89°C
to + 96°C
Warnings: the SCAE protocol provides for the
measurement and evaluation of the infusion wa-
ter temperature under controlled and constant
test conditions using calibrated instruments.
Therefore, every time the infusion temperature is
changed, it is advisable to wait a few minutes to
allow the hydraulic circuit to reach the new ther-
mal stability.