Waldorf RNB8110G Bold 900mm Gas Target Top Static Oven Range

Installation Operation Manual - Page 6

For RNB8110G.

PDF File Manual, 28 pages, Read Online | Download pdf file

RNB8110G photo
Loading ...
Loading ...
Loading ...
4
Specifications
Gas Supply Requirements
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P.
Flue Type: A
1.
* Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and Outer Ring) operating at full setting. Operating pressure is ex-factory set through
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas LP Gas (Propane)
Target Top Oven Target Top Oven
Input Rate (N.H.G.C.)
45 MJ/hr 30 MJ/hr 45 MJ/hr 30 MJ/hr
Gas Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa 2.60 kPa
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas (G20) Propane (G31)
Target Top Target Top
Heat Input (nett)
Nominal
11.5 kW 8.0 kW 11.5 kW 8.0 kW
Reduced
4.7 kW 2.4 kW 7.9 kW 2.4 kW
Gas Rate (nett)
Nominal
1.22 m
3
/hr 0.85 m
3
/hr 0.89 kg/hr 0.62 kg/hr
Reduced
0.50 m
3
/hr 0.25 m
3
/hr 0.61 kg/hr 0.19 kg/hr
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure (*) 9.9 mbar 26.8 mbar
Gas Connection
3
/
4
” B.S.P. Male
Oven Oven
Pilot
200W 170W 200W 150W
Pilot
0.02 m
3
/hr 0.02 m
3
/hr 0.02 kg/hr 0.01 kg/hr
Natural Gas LP Gas
Target Top Oven Target Top Oven
Input Rate (N.H.G.C.)
45 MJ/hr 30 MJ/hr 45 MJ/hr 30 MJ/hr
Gas Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa 2.60 kPa
Gas Connection
3
/
4
” B.S.P. Male
Loading ...
Loading ...
Loading ...