Waldorf RNB8110G Bold 900mm Gas Target Top Static Oven Range

Installation Operation Manual - Page 24

For RNB8110G.

PDF File Manual, 28 pages, Read Online | Download pdf file

RNB8110G photo
Loading ...
Loading ...
Loading ...
22
Gas Conversion and Specifications
- UK Only:
Category: II
2H3P.
Flue Type: A
1.
* Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and outer ring) operating at full setting. Operating pressure is ex-factory set through
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to details in this section for information).
Natural Gas (G20) Propane (G31)
Target Top
Main Burner Injector (Inner Ring)
Ø 1.70 mm Ø 1.10 mm
Main Burner Injector (Outer Ring)
Ø 2.60 mm Ø 1.55 mm
Pilot Burner Injector
0.35 0.25
Burner Aeration Screw X (Inner)
25 mm 20 mm
Burner Aeration Screw Y (Outer)
28 mm 25 mm
Low Fire Adjustment
2
1
/
2
turns out (ccw)
1¾ turn out (ccw)
Oven
Main Burner
Ø 2.60 mm Ø 1.60 mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open Fully Open
Low Fire Screw
Ø 1.5 mm Ø 0.95 mm
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure (*) 9.9 mbar (*) 26.8 mbar (*)
Gas Regulator Cap Screw
Loading ...
Loading ...
Loading ...