Waldorf RNB8110G Bold 900mm Gas Target Top Static Oven Range

Installation Operation Manual - Page 11

For RNB8110G.

PDF File Manual, 28 pages, Read Online | Download pdf file

RNB8110G photo
Loading ...
Loading ...
Loading ...
9
Installation
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as shown in ‘Gas Conversion Section’ in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it
is NOT to be adjusted.
Regulator connections are
3
/
4
" BSP female.
Cconnection to the appliance is
3
/
4
" BSP male.
(Refer to ‘Specifications’ section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
4. Correctly locate appliance into its final operating position and using a spirit level, adjust the legs so
that the appliance is level and at the correct height.
5. Connect gas supply to appliance. A suitable joining compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
6. Check all gas connections for leakages using soapy water or other gas detecting equipment.
7. Check gas operating pressure is as shown in ‘Specifications’
section.
NOTE: Measure burner operating pressure at target top
hob manifold test point with target top burner (Inner
and outer ring) operating at full setting.
8. Verify operating pressure remains correct.
Commissioning
Before leaving the new installation;
Check the following functions in accordance with operating instructions specified in ‘Operation’
section of this manual.
 Light the Target Top Pilot Burners.
 Light the Target Top Main Burners.
 Light the Oven Pilot and Main Burners.
 Check the Oven Main Burner Thermostat operation.
 Check the Low Fire Burner operation for Target Top and Oven.
 Check the High Fire Burner operation for Target Top and Oven.
Ensure operator has been instructed in areas of correct lighting, operation, and shutdown procedure for
appliance.
This manual must be kept by the owner for future reference, and a record of
Date of Purchase,
Date of
Installation
and
Serial Number of Appliance
recorded and kept with this manual. (These details can
be found on Rating Plate attached to lower right hand side of sill panel. Refer to ‘Gas
Connection’ section).
NOTE: If it is not possible to get the appliance to operate correctly, shut off gas supply and contact
supplier of this appliance.
Fig 2
Low Fire
Adjustment
Screw
Manifold
Pressure Test
Point
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
Warning