The Operating Manual of Ice Cream Frying Machine
Ⅰ.The main purpose
Our fried ice machine operating a wide range, flexibility, compared with similar
products, power consumption is extremely small, energy-saving effect is
remarkable. If refrigerated or frozen drinks were fried ice, the better. Especially
for innovative design, the product looks especially luxurious, beauty and health.
Pot which is product configuration is to storage variety of seasonings, produce a
variety of different flavors of fried ice, very compelling. This is suitable for
small-scale self-employed, but also hotels, bars, cold stores essential equipment.
Ⅱ:Technical parameters
Ⅲ:Operation
The plug is inserted in a dedicated ground within three hole sockets, see the
voltage is normal, and then open the "fried ice" switch, over about 2 minutes,
until the pot began to frost, then pour the fried ice beverage, after speculation, if
stick in the pan, shovel it up, just need to hold down (or foot on the foot switch)
"defrosting" defrost switch (each about 10 seconds to loosen defrosting), then
continue to fry ice.
If within three minutes after the shutdown, there is a need to re-fried ice
operation, first a "defrost" operation for 10 seconds, before opening "fried ice"
switch. If it is in three minutes after the operation, you do not need to press
“defrost”button , fried ice can simply press the switch.
Temperature controller usage:
1. Power: The time temperature measurement show when the controller is
powered
2. Parameter setting
(1) In order to prevent misuse and avoid idlers playing, you must double-click
three times "SET" button to enter the setting mode.
(2) The controller into the setting state, first display the minimum temperature
setpoint (Hint symbol "L"), this time press "▲" or "▼" to change the set value,
until it meets the requirements. (When set to a negative value, negative sign
flashing). Then click the "SET", the upper limit of the temperature setting display
(Hint symbol "⺁"), then press "▲" or "▼" to change the set value, until it meets
Model
CBJF-2S5C CBJF-2D5C CBJY-1D6C
Voltage
220V/110V,
50Hz/60Hz
220V/110V,
50Hz/60Hz
220V/110V,
50Hz/60Hz
Power
1060w 1600w 740w
Refrigerant
R410A R410A/R290 R410A/R290
Pan size
35cm 35cm 35cm
Dimension
900×600×770mm 720×540×730mm
Net Weight
60kg 75kg 45kg

the requirements. (When set to a negative value, negative sign flashing). Then
click the "SET", show the compressor stop delay time (Hint symbol "Y"), this time
press "▲" button to change the set value, until it meets the requirements, then
click the "SET" button, the display control mode (the prompt symbol "J") At this
point press "▲" keys to select the cooling mode (Hint symbol "JCC") and heating
mode (Hint symbol JHH). Then click the "SET" button to display the temperature
correction value (Hint symbol "ㄈ"), Normally circumstances does not require
temperature correction; if need for temperature correction, press "▲" or "▼" key
to change the set value, until meet the requirements.
NOTE: The controller has always maintained the upper limit temperature is
greater than the lower limit temperature .
(3) To exit the setting: within sixteen seconds do not press any key, the controller
automatically exit the setting state, the setting value is stored, the display shows
the temperature measurements.
Warning: After setting ,If no waiting for delay ,the power is off, the new set value
will not be stored permanently.
3. Auto run:
(1) The controller is set to cooling mode, then the compressor after power is not
immediately opened, need to wait for several minutes (determined by the Y
value), then the bottom LED point flashes to wait. After the delay time, the relay
follow the measured value and the temperature set upper and lower limits to
determine whether or not the pull, to control the compressor cooling purposes.
(Greater than or equal ceiling work, less or equal to the lower limit off). When
compressor working, the bottom LED point lighting .
(2) If the control mode is heating, opposite to cooling mode. The measured value
is greater than or equal to the upper temperature limit, the relay released; less
than or equal to lower temperature limit, relay closing control heating. When the
heating operation, the bottom LED point lighting.
Note: Machine are freezing ,the compressor needs to delay several minutes each
time then begin to start after power off. Press "▼" key three times to cancel the
delay.
4. Malfunction:
(1) The sensor is open or the measured temperature is less than -50 ℃, Display
-PP.
(2) The sensor is short or the measured temperature is higher than + 50 ℃, the
display shows FF.
(3) After malfunction, the relay is released, the entire display flash dance.
(4)Malfunction eliminated, the display stops flashing jump, still shows
temperature measurements.
Ⅳ:Note
1. The foot switch can be used alone , when inserted into the side of the

fuselage using a dedicated jack, when you need to defrost, the foot on it.
Remove it and put away when not in use.
2. Fried ice machine in the handling and movement, not to exceed 45 degrees
inclination.
3. Do not place the machine in direct sunlight, such as in set up their stalls in
the street, due awning.
4. The machine installation, should be kept out of the wind gate side more than
200mm of space, ensure that the machine cooling.
5. The machine should be operated so that the voltage between 198v-242 v .
6. Fried ice machine outlet, must be single-phase three-hole socket, which must
be firmly grounded plug the on dedicated lines by way related to the earth. Not
with other household appliances in the same outlet.
7. Do not wash the machine with water directly, used towels to wipe cleaning.
Ⅴ:The inspection and handling of troubleshooting
Malfunction Reason Methods
The machine
does not work
1. If the voltage and power
is normal
2. If the power is turned
on or the insurance is
blown
3. If down three minutes
before turning on power
1. Adjusting the voltage
2. The re-plugged or replace
the fuse
3. Turn on the defroster switch
for approximately 10
seconds, or three minutes
after the restart, etc.
Can not make
snow melt
1. If the defrost switch is
in position
2. The sugar of drink is not
enough
1. Turn off the defrost switch
2. Add sugar
Frequent
automatic
transfer
machine
1. If the voltage is normal
2. If the machine’s inlet
and outlet is blocked
3. If is it because of some
reason, the machine
inlet air temperature is
too high
1. Adjusting the voltage
2. Stay out of the wind space
200mm or more
3. Eliminate the cause
Can not defrost 1. Defrost switch is broken
or turned
2. The solenoid valve is
broken or turned
1. Exchange defrost switch or
reconnect
2. The re-plugged or exchange
solenoid valve (change
solenoid valve should be
sent to service points)