9
FIG. 22
Remove the
drain plug
Bottom
drain plug
Continuous
drain hose
WATER DRAINAGE
During dehumidifying mode, remove the drain plug from the
backoftheunit,installthedrainconnector(5/8 universal
femalemender)with3/4"hose(Notincluded).
Formodelswithoutadrainconnector,justattachthedrain
hose to the hole.
Place the open end of the hose directly over the drain area in
yourbasementoor.
P1 CODE WATER DRAINAGE
During normal operation if the water level of the bottom tray
reachesapredeterminedlevel,theunitbeeps8times,and
thedigitaldisplayshows“P1”.
Atthistimetheairconditioning/dehumidicationprocesswill
immediately stop. However, the fan motor will continue to
operate (this is normal).
Carefully move the unit to a drain location, remove the bottom
drain plug and drain the water.
Reinstall the bottom drain plug and restart the machine until
the“P1”symboldisappears.Iftheerrorrepeats,callfor
service.
NOTE: Be sure to reinstall the bottom drain plug