Summit WEM715KW 24" Wide Electric Wall Oven, 115V

Instructions for Use - Page 12

For WEM715KW.

PDF File Manual, 34 pages, Read Online | Download pdf file

WEM715KW photo
Loading ...
Loading ...
Loading ...
12
THREE-WIRE CONDUIT CONNECTION
NOTE: The power cord bracket will have to
be reversed for conduit installations. Detach
the bracket and flip its orientation. Reattach
the bracket to the range so the conduit will
pass through the smaller hole.
120/240 or 240 VAC
If local codes do not allow grounding
through the neutral, refer to the
illustration below of FOUR-WIRE
CONDUIT CONNECTION.
1. Remove the top nuts on the junction
block studs.
2. Tighten the back nuts.
3. Install the terminal adaptor blocks for
bar wire connection. Use the top nuts
removed in step 1.
4. Install the three-wire conduit and an
appropriate strain relief clamp through
the hole in the power cord bracket.
5. Insert the red and black leads into the
outer blocks and the white lead into the
center block. Tighten the set screws.
6. Secure the strain relief clamp around the
conduit and tighten the nut against the
power cord bracket.
120/240 VAC
FOUR-WIRE CONDUIT CONNECTION
NOTE: The power cord bracket will have
to be reversed for conduit installations.
Detach the bracket and flip its orientation.
Reattach the bracket to the range so the
conduit will pass through the smaller hole.
1. Remove the top nuts on the junction
block studs. Then, tighten the back nuts.
2. Cut the ground strap as close to the
junction block as possible and at the
lower section with upturned sides.
3. Install the four-wire conduit and an
appropriate strain relief clamp through
the hole in the power cord bracket.
4. Use the section of ground strap with
upturned sides and the ground screw to
connect the ground lead below the
junction block.
5. Install the terminal adaptor blocks for
Effective January 1, 1996 the National Electrical
Code requires that new construction (not
existing) utilize a 4-conductor connection to an
electric range.
NOTE: A 4-conductor connection is to be used
when the appliance is installed in a mobile home
or when local codes do not permit grounding
through the neutral.
bar wire connection. Use the top nuts
removed earlier in step 1.
6. Insert the red and black leads into the
outer blocks and the white lead into the
center block. Tighten the set screws.
7. Secure the strain relief clamp around the
conduit and tighten the nut against the
power cord bracket.