9
Alternative method: self-leveling cement is recommended for large surfaces and the following
floor materials: engineered wood, laminate, floating floors, vinyl, linoleum and
carpet.
2.3 Heatwave® typical installations and applications
Consult the manufacturer for information on special installation
requirements for carpets, wood, laminate and vinyl or linoleum flooring.
Read the instructions carefully before installing Heatwave® system.
Remember to measure the resistance four times.
Do not install Heatwave® in walls or ceilings.
The cable must be embedded in cementitious material.
The minimum installation temperature is 40ºF (5°C ).
The heating cable cannot be cut to length, crossed over itself, or installed too close to itself.
Use copper conductor feeder wire only.
Remember to check that the supply voltage matches the voltage of the Heatwave.
Remember to place the labels as written in this instruction.
Only for indoor installation.
Metal structures or materials used for the support of or on which the Heatwave® is installed
must be grounded in accordance with applicable CSA or NEC requirements.
Please consult Heatizon Systems for any other questions.
NOTE: