124
9.1.2 Configuring Temperature Contrast
Compares temperature of spots, lines or area that you have selected and displays comparison results
on the image.
Prerequisites
You have configured at least two temperature measurement rules. For details, see "9.1.1 Configuring
Parameters".
Procedure
Step 1 Select
Temperature Measurement
>
Rule
>
Temperature Contrast
.
Figure 9-2 Temperature contrast
Step 2 Click
Add
to add a temperature comparison group.
Step 3 Click to enable the temperature comparison group, and then configure the
parameters.
The temperature comparison group is enabled by default.
Table 9-2 Temperature comparison group
Parameter Description
Temp Different Select the targets for contrast.
Alarm Condition
Set the alarm condition: Alarm result + alarm condition + Alarm
threshold temperature.
Alarm result: Select from the following three options to
determine a standard of triggering an alarm..
Average temperature: Compare average temperatures of
two rules.
Maximum temperature: Compare maximum temperatures
of two rules.
Minimum temperature: Compare minimum temperatures
of two rules.
When one of the two rules is a spot, both maximum
temperature and minimum temperature are actually
average temperature.
Alarm condition:
Below
,
Match
and
Above
.
Alarm threshold temperature: The temperature that triggers
alarm, and it ranges from–40 °C to 550 °C.