5.Advanced User Guidebook
75
Figure 5-74 CURS MEAS Menu
The description of the cursor measurement menu is shown as the following table:
Function
Menu
Setting Description
Type
OFF
Vamp
Freq
Switch off the cursor measurement.
Display the Vamp measurement cursor and menu.
Display the Freq measurement cursor and menu.
Source
Math FFT
Display the channel for the cursor measure.
When carrying out the cursor measurement, the position of Cursor 1 can be adjusted with
the VERTICAL POSITION knob of Channel 1, and that of Cursor 2 can be adjusted
with the VERTICAL POSITION knob of Channel 2.
Perform the following operation steps for the Vamp cursor measurement:
1. Press Cursor and recall the Cursor Measure menu.
2. Press the H1 button, the Type menu will display at the right of the screen. Press the
F2 button to select Vamp for Type, with two purple dotted lines displayed along the
horizontal direction of the screen indicating Cursor1 and Cursor2.
3. According to the measured waveform, adjust the positions of Cursor1 and Cursor2 by
turning the VERTICAL POSITION knob of CH1 and CH2. Cursor increment
window at the left bottom shows absolute value of the two cursors amplitude
difference and the present position.