16
Maintenance
Fuse Test
FUSE TEST
WARNING: Always perform a Fuse Test before using the internal current shunt measurement mode.
1. Perform a resistance measurement with the C and Ω terminals connected
2. If the resistance measured is greater than 0.5Ω, replace the
fuse*
* The resistance mode on the Innova Multimeter is not accurate below
1Ω. The actual resistance of the fuse should be 20mΩ.
FUSE REPLACEMENT
WARNING: Only use appropriately rated replacement fuse.
1. Open the DS200 Multimeter per directions above.
2. Gently remove existing fuse from holder.
3. Replace fuse only with appropriately rated replacement.
4. Recommended model:
Reomax 632.300.12
Size 3AG 12A hold 600V 10kA minimum interrupt
5. Close the Innova Multimeter per directions above.