MANUAL FOR PORTABLE HEATING SEALER
FKR-200 300 400
Read this manual carefully prior to use.
Technology is subject to change without further notice.

1 SPECIFICATION.
2 A film available
1) Power: A single phase current(AC)220V.50/60Hz
2) Power consumption : 300W/400W/500W
3) Sealing width : 10mm
4) Sealing length : 200/300/400mm
5) Temperature control : 0 150 (By bimetal)
6) Heating type : Series type
7) Preheatingg : ABT 1 minute
8) Dimension : 300(W)*360(D)*125(H)mm
9) Weight : ABT 1.4kg
Coating film, Metalized film, Laminated film on thermo-plastice film and
Aluminum film, Foils or varnish film, wax coating film and so on.
-1-
-2-
3 Features
1) It can be used at any place easily and it is handy to carry.
2) It can seal a film regardless of its volume or size.
3) With special materials for heating wire in heating jaws, the life of heating
wire is much longer than other machines.
4) With adjuster for heat temperature, user can control heating temperature
,
according to user s taste.

4 Title of parts
5) With light material for sealing jaws, it is easy to carry it anywhere and to
use in narrow place.
6) With coating of special strong hardness for sealing jaws, it would not change
in appearance for long thime using.
7) It can seal special material like Aluminum film whose apperance will not be
changed for long thime, and thick film which is impossible to be sealed by
impulse sealer.
-3-
-4-
sealing bar
pressure lever
power lemp
healing lemp
adjuster

6 Part List
5 Disassemble
-6-
-5-
NO
Name
Ouantity Standard
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Lever(up)
Lever cover(up)
Insulation plate
Circuit set
Below board
Supporter
Heating bar(down)
Heater
M10 Bolt
Shaft
Plain washer
M6 Bolt
Stainless bolt
Plain washer(SUS)
1
1
1
1
1
2
1
4
4
1
2
2
4
16
NO
Name
Ouantity Standard
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Epoxy washer
Aluminum
Nylon nut
Insulation cover
Lever(down)
Spring
Plate board
Lever cover
Volume
Bimetal
Heating bar(up)
Code rock
Stainless nut
16
8
4
1
1
1
1
1
1
1
1
1
8

7 Troubles
-7-
Trouble
Reason
Remark
No power and no heating
Power on but no heating
Bad sealing
Weak sealing
Unable to control heat
Disconnection of wire
Cable of the heating part broken or
heater broken
Uneven sealing bar
Low heating temperature, Low
pressurization. Short pressing time
Defected heat odjuster