- 5
Rinse the high pressure module with a anti-
frost solution before shutting down the high
pressure module during the frost period.
CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
The bases of a safe operating of the equip-
ment is the regularly maintenance accord-
ing to the following maintenance plan.
Use exclusively original parts of the manu-
facturer or those parts recommended by
him like
replacement and wear parts
Accessory parts
Fuel
Detergent
DANGER
Risk of electric shock!
Remove the voltage from the high pressure
module; for this, switch the high pressure
module main emergency stop switch to “0”
and secure it against being switched on
again.
Operator
Work designated with the sign “Operator”
may only be carried out by persons who
have been instructed in the safe operation
and maintenance on the wash plant
Customer Service
Work designated with the sign “Customer
Service” may only be done by the fitters of
Kärcher Customer Service.
In order to guarantee a reliable operation of
the equipment, we success, you signed a
maintenance agreement. Please refer to
your local Kärcher service department.
1 Bypass valve
2 Screw for manual switching
Shutdown
Transport
Storage
Technical specifications
HD 30/6 HD 60/6 K2 HD 60/10 K2
High pressure part
Flow rate l/h (l/min) 1 x 3050 2 x 3050 (2 x 50,8)
Operating pressure MPa 6,0 10,0
Permissible pressure MPa 8,7 11,5
Water connection
Flow quantity l/h (l/min) 1 x 3000 2 x 3000 (2 x 50)
Max. feed temperature °C 40
Flow pressure (with ABS storage tank) MPa 0,4...0,6
Flow pressure (with constructed storage tank) MPa 0,1
Diameter inlet (with ABS storage tank) mm 1x19 2x19
Diameter inlet (with constructed storage tank) mm 50
Electrical connection
Current type Hz 50, 3~
Type of protection IPX5
Voltage V 400, IEC 38
Power Input kW 15 23
Dimensions and weights
Dimensions (high pressure module) l x b x h mm 1100x640x930
Dimensions (high pressure module with ABS storage tank) l x b x h mm 1100x790x1490
Weight (high pressure module) kg 145 200 250
Weight (high pressure module with ABS storage tank, empty) kg 163 235 285
Tank capacity of ABS storage tank l 1x85 2x85
Oil quantity for each pump casing l 1,3
Noise emission
Sound pressure level (DIN EN ISO 11201:2010) dB(A) 87
Maintenance and care
Maintenance instructions
Who may carry out maintenance and
servicing?
Maintenance contract
Maintenance overview report