E
Do not store your laser in the kit box if the laser is wet. The laser
should be dried first with asoft dry cloth.
NOTE: Disassembling the laser level will void all warranties on the
product.
Cleaning
Exterior plastic parts may be cleaned with adamp cloth. Although
these parts are solvent resistant, NEVER use solvents. Use asoft, dry
cloth to remove moisture from the tool before storage.
Field Calibration Check
CHECKING ACCURACY – HORIZONTAL BEAM, SCAN DIRECTION (FIG. 5)
Checking the horizontal scan calibration of the laser requires two walls
9 m (30') apart. It is important to conduct acalibration check using
adistance no shorter than the distance of the applications for which the
tool will be used.
TABLE 1
Distance Allowable Distance
Between Walls Between Marks
9.0 m (30') 3.0 mm (1/8")
12.0 m (40') 4.0 mm (5/32")
15.0 m (50') 5.0 mm (7/32")
1. Attach the laser to awall using its pivot bracket, with the laser
facing straight ahead toward the opposing wall (0 degree position).
2. Turn on the laser’shorizontal beam and mark the beam position on
the opposing wall directly across from the laser. Always mark the
centre of the beam’sthickness.
3. Pivot the laser to the extreme left (–90 degree position) and mark
the beam position on the opposing wall.
4. Pivot the laser to the extreme right (+90 degree position) and mark
the beam position on the opposing wall.