DW089/DW089CG
18
E
• Do not store your laser in the kit box if the laser is wet. The laser
should be dried first with asoft dry cloth.
NOTE: Disassembling the laser level will void all warranties on the
product.
Cleaning
Exterior plastic parts may be cleaned with adamp cloth. Although
these parts are solvent resistant, NEVER use solvents. Use asoft, dry
cloth to remove moisture from the tool before storage.
Field Calibration Check
CHECKING ACCURACY – HORIZONTAL BEAM, SCAN DIRECTION (FIG. 5)
Checking the horizontal scan calibration of the laser requires two walls
9 m (30') apart. It is important to conduct acalibration check using
adistance no shorter than the distance of the applications for which the
tool will be used.
TABLE 1
Distance Allowable Distance
Between Walls Between Marks
9.0 m (30') 3.0 mm (1/8")
12.0 m (40') 4.0 mm (5/32")
15.0 m (50') 5.0 mm (7/32")
1. Attach the laser to awall using its pivot bracket, with the laser
facing straight ahead toward the opposing wall (0 degree position).
2. Turn on the laser’shorizontal beam and mark the beam position on
the opposing wall directly across from the laser. Always mark the
centre of the beam’sthickness.
3. Pivot the laser to the extreme left (–90 degree position) and mark
the beam position on the opposing wall.
4. Pivot the laser to the extreme right (+90 degree position) and mark
the beam position on the opposing wall.