Kenmore 2539753111 Air Conditioner

Owner’s Guide - Page 9

For 2539753111.

PDF File Manual, 20 pages, Read Online | Download pdf file

2539753111 photo
Loading ...
Loading ...
Loading ...
Before You Call for Before calling for service, review this list, It may save you time and expense This fist
includes common occurrences that are not the result of defective workmanship or
Service ,,,materials in this appliance
OCCURRENCE SOLUTION
Air conditioner will not operate. Wall plug disconnected Push plug firmly into wall outlet
House fuseblown or circuit breaker tripped Replacefuse with time delaytype or resetcircuit breaker
FAN selector in OFFposition Turn FAN selector to the desired FAN setting
Unit turned off bymoving TEMPControl to a warmer setting and then immediately turning back
to a colder setting Wait approximately 3 minutes Listen for compressor to start,
Unit turned off and then on too quickly Turn unit off and wait 3 minutes before restarting
TEMP Control set warmer than room temperature Turn TEMP Control clockwise to a colder setting
(thick rule)
Air from unit does not feel cold Turn selector to a higher FAN position
enough. TEMP Control set too warm (thin rule) Turn TEMPControl clockwise to a colder setting (thick rule)
Roomtemperature below 70°F(21°C) Cooling may not occur until room temperature risesabove
70°F(21°C)
Temperature sensingtube touching cold coil, located behind airfilter Straighten tube away from coil
Air conditioner cooling, but room is Outdoor temperature below 70°F(21°C) To defrost the coil, set selector to FAN position Then,
too warm - - ice forming on cooling turn TEMP Control clockwise to a warmer setting (thin rule)
coil behind decorative front. Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost, set selector
to FAN
TEMP CONTROL set too cold for night-time cooling To defrost the coil, set selector to a FAN
position Then, set TEMP CONTROLto a warmer position
Air conditioner cooling, but room is Dirty air filter--air restricted Clean air filter Refer to Care and Cleaning section
too warm -_ NO ice forming on
cooling coil behind decorative front. TEMP Control set too warm Turn TEMP Control clockwise to a colder setting (thick rule)
Vent set at OPEN position Set vent at CLOSEDposition for maximum cooling
Air directional louvres positioned improperly Position louvres for better air distribution
Front of unit isblocked by drapes, blinds, furniture, etc -- restricts air distribution Clear blockage
in front of unit
Doors, windows, registers, etc open --cold air escapes Close doors, windows, registers, etc
Unit recently turned on in hot room Allow additional time to remove "stored heat" from walls,
ceiling, floor and furniture
Dirty air filter-- air restricted Clean air filter
Air conditioner turns on and off Outside temperature extremely hot Set FAN on high speed to bring air past cooling coils more
rapidly frequently
Noise when unit is cooling, Air movement sound This is normal If too loud, turn selector to lower FAN setting
Sound of fan hitting water-moisture removal system This is normal when humidity ishigh Close
doors, windows and registers
Window vibration--poor installation Refer to installation instructions or check with installer
Water dripping INSIDE when unit is Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer
cooling° to installation instructions--check with installer
Water dripping OUTSIDE when unit Unit removing large quantity of moisture from humid room This is normal during excessively
is cooling, humid days