FlexFit Pro
ENGLISH
Press the SET key. The swing louver function icon
will be displayed. Press the  keys to advance
through the functions to select the SLEEP func-
 keys to set the
will remain on.
If neither  key is pressed within 10 seconds, or if the
MODE, FAN, or ON/OFF keys are pressed prior to pressing the
SET key, the setting function is canceled and reverts back to
the previous setting.
To cancel the Sleep function. Press the SET key. The swing
louver function icon will be displayed. Press the  keys to
advance through the functions to select the SLEEP function.
function.
NOTE: This function requires the ON/OFF key LED to be
turned ON and the screen backlight to be illuminated.
Sleep Function
the indoor unit has reached 500 hours of operat-
ing time.
the icon and reset the operating time.
NOTE: This function requires the ON/OFF key LED to be
turned ON and the screen backlight to be illuminated.
Filter Cleaning
WIRED CONTROLLER OPERATION
Settings & Functions
Press the SET key. The swing louver function icon
will be displayed. Press the  keys to advance
through the functions to select the Heat Reclaim
To cancel the Heat Reclaim Ventilation function, repeat the
above steps.
If neither  key is pressed within 10 seconds, or if the
MODE, FAN, or ON/OFF keys are pressed prior to pressing the
SET key, the setting function is canceled and reverts back to
the previous setting.
This function is reserved for future models.
NOTE: This function requires the ON/OFF key LED to be
turned ON and the screen backlight to be illuminated.
Heat Reclaim Ventilation
Note: These functions require the ON/OFF key LED to be
turned OFF and the screen backlight to be illuminated.
Auto Restart
Setting DIP switch SW1-4 located on the PCB of the wired
control to the onposition will disable the auto restart func-
enabled (default position). When the switch is in the “on”
posi
-
tion, auto-restart is disabled.
Information retained in auto-restart are: Mode, Fan Speed,
Temperature Setting, Swing State, and Heat Reclaim Ventila-
tion function.
Communication Error of Wired Controller
If there is no communication between the wired controller and
indoor unit for 4 minutes, when checking error codes,
“07 will be displayed in the upper right corner of the display.
Other Functions