26
- All Other Markets:
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Open Burner
Main Burner Ø 2.45mm Ø 4.50mm
Pilot Burner ('PF' Option Only) 0.30 0.60
Griddle
Main Burner Ø 2.10mm Ø 3.40mm
Pilot Burner 0.35 0.60
Burner Aeration Setting Fully open Fully open
Oven
Main Burner Ø 2.6mm Ø 5.0mm
Pilot Burner 0.35 0.60
Burner Aeration Setting Fully Open Fully Open
Supply Pressure 1.13 - 3-4 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*) 0.95 kPa 0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to Burner Operating
Pressure specified).
Open Burner
Main Burner
Ø 1.50mm Ø 1.40mm
Pilot Burner ('PF' Option Only)
0.20 0.20
Griddle
Main Burner
Ø 1.30mm Ø 1.20mm
Pilot Burner
0.23 0.23
Burner Aeration Setting
Fully open
Oven
Main Burner
Ø 1.60mm Ø 1.45mm
Pilot Burner
0.23
Burner Aeration Setting
Fully Open
Supply Pressure
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa
Gas Regulator Cap Screw