15
1. Ensure oven door is closed.
2. Turn ONelectrical power at mains supply, (white) power indicator light will illuminate on oven
control panel.
3. With pilot burner alight, depress and rotate oven gas control knob to 'Main Flame' position. (This
puts gas valve in 'Stand-By' position and control of main burner is now carried out through oven
thermostat control).
4. Turn oven thermostat to desired oven temperature setting required, this will regulate gas supply to
oven main burner.
5. Oven fan will start up and oven main burner will ignite.
6. Amber heating indicator light will show that oven main burner is ONand oven is heating. When
amber heating indicator light goes out, oven has reached pre-selected temperature, burner will cycle
OFF’.
1. Fan is operational only when oven thermostat is set to a temperature. Fan is controlled by a
microswitch which in turn is controlled by opening and closing oven door. Oven fan is operational
only with oven door closed.
1. To turn Offoven main burner / heating, set oven thermostat to '0' temperature position, this will
turn oven main burner OFF’, but will leave oven pilot burner ON’.
2. In this position pilot burner will remain alight, but oven main burner will not operate until thermostat
control knob is set to a temperature.
3. If oven pre-heating is required, set thermostat control knob to temperature 190°C and allow 20
minutes before cooking in oven to allow oven to warm up.
1. To Shut Downoven, turn oven thermostat to 0’ position, oven main burners will go out.
2. Turn gas control valve to 'OFF' position and this will extinguish pilot burner. (To relight pilot burner,
refer to Oven Pilot Ignitionabove).
3. Turn OFFelectrical power at mains supply, (white) power indicator light will extinguish.
NOTE: If main burner has recently been turned 'OFF', should you wish to re-light oven, the
interlock will not allow gas valve to be turned to main burner position until interlock has
reset (Approximately 1 minute). DO NOT FORCE GAS VALVE TO MAIN BURNER POSITION
UNTIL INTERLOCK HAS RESET, as this will damage gas control valve.
Should any abnormal operation like;
- ignition problems,
- abnormal burner flame,
- burner control problems,
- partial or full loss of burner flame in normal operation, appliance requires IMMEDIATE
service by a qualified service person and should not be used until a service is carried out.