10
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
* Side clearances can be 50mm when the adjacent surface is at least 100mm below cooking surface.
NOTE:
All Models are delivered completely assembled. No further assembly is required.
This appliance is fitted with adjustable feet to enable appliance to be positioned securely
and level. This should be carried out on completion of gas connection. Refer to Gas
Connectionsection.
Optional Accessories (Refer to Replacement Parts List)
Plinth Kit. For installation details, refer to instructions supplied with each kit.
Rear Adjustable Legs.
1. Check that all feet (or castors) are securely fitted.
2. Adjust feet to make convection oven range steady and level.
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON.
1. It is essential that gas supply is correct for appliance being installed and that adequate supply
pressure and volume are available. The following checks should be made before installation:-
a. Gas Type the appliance has been supplied for is shown on
coloured stickers located above gas connection and on rating
plate. Check that this is correct for gas supply, appliance is being
installed for. Gas conversion procedure is detailed in this manual.
b. Supply Pressure required for this appliance is shown in
Specifications section of this manual. Check gas supply to ensure
adequate supply pressure exists.
c. The Input Rate of this appliance is shown on Rating Plate and in
Specifications section of this manual. Input rate should be
checked against available gas supply line capacity. Particular
note should be taken if appliance is being added to an
existing installation.
NOTE: It is important that adequately sized piping runs directly to connection joint on appliance
with as few tees and elbows as possible to give maximum supply volume.
2. Fit gas regulator supplied, into gas supply line as close to appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as shown in Gas Conversion Sectionin this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it
is NOT to be adjusted.
Rating Plate
Location
Fig 1
Left / Right hand side 250mm (*) 0mm
Rear 100mm 0mm