PROBLEM POSSIBLE CAUSE SOLUTION
During a cycle comes
on, accompanied by an
audible signal.
Display ERROR03
The vacuum is not activated.
The lid has not been closed.
There is dirt on the seal of the lid.
The lid seal is broken.
The pump won’t start. The pump
protection has been activated.
When the cycle has been started,
gently press the lid to activate
the vacuum.
Clean the tray and the seal.
Contact the Technical Support
service for replacement.
During a cycle with
external container
comes on accompanied by
an acoustic signal.
Display ERROR03
The lid of the external container
is not positioned correctly.
The external suction device was
not properly connected.
Correctly position the lid of the
external container.
Correctly connect the external
suction device to the packaging
machine and to the container.
The cycle completes, the
symbol
flashes along
with an acoustic warning.
Display ERROR04
Vacuum sensor fault.
Contact the Technical Support
service.
It comes on
and
flashes.
Display ERROR05
Many consecutive cycles were
performed and the oil in the
pump has overheated.
Switch off the appliance and
allow it to cool down.
If the problem persists when the
machine is switched back on, call
the after sales service.