6. Preparation Instructions
Continuous Drainage Mode
For operations requiring larger amounts of moisture to
be extracted, a Ø12mm discharge hose (supplied) can be
tted to the water tank outlet through the water tank
hose port (9). When operating in this mode, the
dehumidier will run continuously until it is manually
switched o.
4 Fig.
(9)
Important: Ensure that the receptacle is large enough to
accommodate the amount of moisture that will be
extracted during the operating time. The product will
NOT stop operating if the receptacle is lled.
Important: Remove the outlet bung before connecting a
discharge hose. The discharge point of the hose MUST
be lower than the water tank outlet in order for water to
be continually discharged from the unit. Ensure that the
hose is not bent or kinked and does not contain any
upward stretches.
Draper Tools recommends locating the discharge point
in a permanent drain or closed-top container to prevent
the moisture from being recycled through the
dehumidier once it has been discharged.
This product may be used with an external uplift pump
(not supplied) for low-level applications.
Important: Ensure that the water discharged from the
hose does not create a slipping hazard.
6.3 Positioning the Dehumidier
Failure to position the dehumidier correctly will
adversely impact on its performance.
Important: DO NOT move the dehumidier if the internal
tank contains water as it may tip over and cause a
spillage. ALWAYS drain the water tank before moving the
unit.
• Allow at least 50cm of clear space around the sides
and rear of the unit.
• Allow at least 1m of clear space at the front of the unit.
• Position the unit in a clear and central location.
• For maximum eciency, create an enclosed
environment by closing all doors and windows.
Important: The enclosed area MUST be larger than
the minimum room size rated for the unit.
• When used in a home, ensure that all external
openings are closed and open all appropriate interior
doors, with the unit located in a central location.
• If moisture or dampness is particularly prolic in one
specic area, position the unit closer to that location
before moving to a more central spot.
5 Fig.
≥ 50cm
≥ 50cm
≥ 1m
≥ 50cm
WARNING! Position the unit on sturdy at and
level surfaces ONLY. NEVER position the unit on
sloped surfaces as it may tip over and cause
injury or damage.
CAUTION! DO NOT position the unit in close
proximity to radiators or other heat sources.
CAUTION! When using the dehumidier to dry
wet materials, position the unit at least one
meter from the items to be dried. This prevents
water from falling onto the unit and damaging
internal components.
– 11 –