LX Series Direct Vent Gas Fireplace


Plan for the installation of your appliance. This includes
determining where the unit is to be installed, the vent con-
guration to be used, framing and nishing details, and
whether any optional accessories (i.e. blower, wall switch,
or remote control) are desired. Consult your local building
code agency to ensure compliance with local codes, includ-
ing permits and inspections.
The following factors should be taken into consideration:
Clearance to side-wall, ceiling, woodwork, and windows.
Minimum clearances to combustibles 

This replace may be installed along a wall, across a
corner, or use an exterior chase. Refer to Figure 4 for
suggested locations.
Location should be out of high trafc areas and away
from furniture and draperies due to heat from appli-
ance.
Never obstruct the front opening of the replace.
Do  install in the vicinity where gasoline or other
ammable liquids may be stored.
Vent pipe routing. See VENTING section found in this
manual for allowable venting congurations.
These units can be installed in a bedroom. See National
Fuel Gas Code ANSI Z233.1/NFPA 54 (current
edition), the Uniform Mechanical Code — (current edi-
tion), and Local Building Codes for specic installation
requirements.
Y
E
A
B
C
D
F
Y
B
X
Figure 4 -
Locating Gas Fireplace
** Island (C) and room divider (D) installation is possible as long
as the horizontal portion of vent system (X) does not exceed
20'. See Installing Horizontal Termination Conguration on
Pages 20 and 21.
* When you install your replace in (D) room divider or (E)
at on wall corner positions (Y), a minimum of 6" clearance
must be maintained from perpendicular wall and front of
replace.
A Flat on Wall
B Cross Corner
C Island**
D Room Divider*
E Flat on Wall Corner*
F Chase Installation
Y 9" Minimum