51D0528
35
LX Series Direct Vent Gas Fireplace


You may check for gas leaks with the following
methods only:
Soap and water solution
An approved leak testing spray
Electronic sniffer
 



1. Depress and turn knob counterclockwise
to
pilot position.
2. Depress fully and hold pilot gas knob. Depress piezo
ignitor as many times as needed to ignite the pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
Figure 49 -
Pilot Position
Check for gas leaks in each of the following locations:
Pipe from the gas supply line connection to the gas valve
Burner connections Field made joints / gas shutoff valve
Pilot Factory made joints
Each joint or connection All joints on valve and control body




    




PILOT
O
F
F
P
I
L
O
T
O
N