LX Series Direct Vent Gas Fireplace

HOT
Figure 17 -
Installing Horizontal Vent Cap
Vent Cap
Apply Mastic to
All Four Sides
Deecting Shield
Wood Screw
FP2715
For vinyl siding, stucco, or wood exterior use vinyl siding
standoffs between vent cap and exterior wall. The vinyl
siding standoff prevents excessive heat from melting the
vinyl siding material. Bolt the vent cap to the standoff. Apply
non-hardening mastic around outside edge of the standoff
instead of the vent cap assembly. Use wood screws pro-
vided to attach the standoff. Figure 18
HOT
Figure 18 -
Install Vinyl Siding Standoff
Apply Mastic to
All Four Sides
Cut Vinyl Siding Away
to Fit Standoff
Wood Screw
Vent
Cap
Screw
Standoff
Deecting Shield
FP2716
Figure 19 -
Connect Vent Cap with Horizontal Vent Pipe
Interior Wall
Surface
Fire Stop
Assembly
Horizontal
Vent Pipe
Screw
Vent Cap
(Horizontal
Termination)
FP1957






The Vent Graph, showing the relationship between vertical
and horizontal side wall venting, will help to determine the
various dimensions allowable. Refer to Page 16

      

When vent termination exits through foundations less than
20" below siding outcrop, the vent pipe must ush up with
the siding.
It is best to locate the replace in such a way that minimizes
the number of offsets and horizontal vent length.

      
     

     
    


The horizontal vent run refers to the total length of vent
pipe from the ue collar of the replace (or the top of the
Transition Elbow) to the face of the outer wall.
The maximum number of 90° elbows per side wall
installation is three (3). Figure 20
If a 90° elbow is tted directly on top of the replace
ange the maximum horizontal vent run before the ter-
mination or a vertical rise is 36” (914 mm). Figure 21
If a 90° elbow is used in the horizontal vent run (level
height maintained) the horizontal vent length is reduced
by 36" (914 mm). This does not apply if the 90° elbows
are used to increase or redirect a vertical rise. Figure
23
5. Slide re stop over the vent pipe before connecting the
horizontal run to the vent cap. Figure 19
6. The pipe overlap should be a minimum of 1Z\v". Apply
silicone to the outer pipe connection. Fasten all vent
connections with screws provided.
7. Slide re stop against the interior wall surface and attach
with screws. Figure 19