8. Turn on the grill and turn the Temperature Dial to any setting desired. With
the lid closed, preheat the grill for 10 minutes before placing food.
2.Shutdown Cycle
Auger turns off
Fan continues to run for 5 minutes
After finished cooking, turn the Temperature Dial to Shutdown Cycle position, the
function of this setting to leave the Draft Induction Fan running for 10 minutes to burn
redundant pellets in the fire pot. After the fan runs for 10 minutes the fan will stop
running and the controller will power off.
CAUTION: The main power switch will shut the power off to the controller and the
Temperature Dial Knob switch will cut off power to the grill components only. When
servicing the controller or any parts, ensure that the power supply is disconnected to
avoid a shock hazard.
Error codes:
LEr (Low Temperature Alarm)
Grill temp was below 150F for more than 20 minutes.
HEr(High Temperature Alarm)
Grill temp reached 550F.
Er1
Check to ensure the temperature probe is properly connected.
Er2
Shut off the grill, wait three seconds and restart. This will reboot the controller and
fix the problem. If that doesn’t work they should call customer service
ALWAYS TURN THE UNIT TO SHUTDOWN ON THE CONTROL PANEL WHTN GRILLING
IS COMPLETED. Do not turn the switch to the Off position until the unit has completely
shut down. Failure to follow this procedure may result in a fire.