Door Sensor Replacement
1. Prepare the metal surface of the cabinet flange, use the first alcohol cloth to remove any
dirt or residue from the previous sensor.
2. Do not remove the adhesive backing from sensor until it is in place.
3. Slide the new sensor into the gap between the bottom flange and trim piece.
4. Once the sensor is in place:
a. Remove the adhesive backer from sensor.
b. Ensure the sensor is in position and carefully adhere to the cabinet. Apply
carefully using thumb pressure to the outer perimeter of the door sensor.
c. NOTE: Care should be taken not to apply unnecessary pressure directly on the
raised vertical center of the sensor face. The switch is pressure sensitive; any
undue pressure could damage the sensor.
5. Replace the toe grill.
NOTE: A new door gasket with a stronger magnet was introduced into production at the end
of April 2015.
The starting Serial Number for this change was 20150421xxxH. All units produced after this
date will incorporate the new door gasket.
Anytime the above service kits (S41050470-varient) are ordered for a serial number built
prior to 20150421xxxH, a new door gasket, with stronger magnet should also be ordered.
ALWAYS LOCATE AND POSITION THE SENSOR FROM THE HANDLE SIDE OF THE
CABINET.
NOTE: Prior to removing the backing from the sensor, the surface of the cabinet
flange needs to be prepared using an alcohol wipe to remove any dirt or residue.
1) The front vertical edge of the sensor (B) is located 5 ¼” (5.25”) from the
inside of the cabinet flange (A).
2) Locate the top of the sensor along the top edge of the bottom cabinet
flange (C).