Loading ...
Loading ...
Loading ...
© 2021 United States Stove Company
5
INSTALLATION
of the fuel loading and ash removal openings. Floor
protection must extend under and 2” (51 mm) to each side
of the chimney tee for an interior vertical installation.
Canada: Require a minimum of 450 mm [17.7”] beyond the
front of the unit and 200 mm [7.8”] beyond each side of the
unit. A Floor Protector of 1/4” thick is recommended for
this installation.
FLOOR PROTECTOR
A
C C
B
A Rear 1” 25 mm
B Front 6” 152 mm
C Side 6” 152 mm
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home in accordance with the
clearances given below. For safety reasons, please
adhere to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be done
by means approved by a regulatory authority.
D Backwall to unit 8” 203 mm
E Sidewall to ue 12-1/2” 317 mm
F
Sidewall to top edge of
unit
8” 203 mm
G Backwall to Flue 2” 50 mm
H Adjacent wall to unit 3” 76 mm
J Alcove depth 36” 914 mm
K Alcove height 60” 1524 mm
E
D
G
F
E
F
BACK WALL
SIDEWALL
BACK WALL
SIDEWALL
H
H
H
H
J
K
OUTSIDE AIR SUPPLY (OPTIONAL, UNLESS
INSTALLING IN A MOBILE HOME)
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK, AWNING,
OR IN ANY SEMI ENCLOSED OR ROOFED AREA. DOING
SO MAY RESULT IN UNPREDICTABLE AIRFLOW AT THE
VENT CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE, AS
WELL AS, OTHER UNFORESEEABLE ISSUES.
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home.
You can purchase the 69FAK through your heater dealer.
Installation instructions are supplied with the air intake kit.
Loading ...
Loading ...
Loading ...