Page 22 of 66
WARNING: Grills with a total BTU’s output less than 80,000 BTU’s can only be
connected to 20 lbs. propane cylinders (See Table1 and 2 for BTU requirements).
WARNING:
The propane tank strap provided must be used to hold the propane
cylinder in place. Failure to do so can cause damage to the gas supply hose and
increases the risk of fire causing death or serious injury (See “Figures 4-6”) for further
detail.
For built-in applications, not using a Crown Verity built-in cabinet, the propane
cylinders must be integrally mounted. An integral mounting means shall be provided
on the outdoor cooking gas appliance for mounting the LP gas supply cylinder(s).
Integral retention means shall be provided on the outdoor cooking gas appliance to
limit the movement of the LP gas cylinder(s). Lateral movement shall not exceed 1 in
(25.4 mm) at the retention means, and the cylinder(s) or any portion thereof shall not
become dislodged from its (their) retention means when a lateral force equal to the
full weight of the cylinder(s) is applied in any direction at the center of the vertical
height of the cylinder(s). If the means is for attachment to the protective collar of the
cylinder(s) it shall not interfere with the operation of the cylinder(s) valve(s). Any
movement shall not transmit strain to rigid tubing or pipe connections. Mounting and
retention means shall incorporate adequate adjustments to accommodate the size of
the cylinder(s) specified by the manufacturer.
WARNING:
For Pr
opane Gas Models: Your grill/side burner is designed to operate on L.P.
(propane) gas pressure regulated at 11” water column. The regulator(s) supplied with the grill
are set to this pressure and must be used.
Connection:
The Type I (Q.C.C.1) cylinder valve is recognizable by the large external thread on
the outlet part of the valve. Standard valves do not have these exterior threads. Any attempt to
fit the regulator(s) with anything other than the mating Type I (Q.C.C.1) connector, (recognized
by the large plastic features designed into the Type I (Q.C.C.1) system. Fitting a standard #510
P.O.L connector, will not provide the flow control or temperature shut-off safety features built
into the complete Type I (Q.C.C.1) system. This regulator is equipped with the Type I (Q.C.C.1),
quick closing connection system, which incorporates the following features:
Will not allow gas to flow until a positive seal has been made.
Has a thermal element that will shut off the flow of gas if subjected to temperatures
between 115° and 150°C (240° & 300°F).
Has a flow limiting device which, when activated, will restrict the flow of gas to 10 cubic feet
per hour (25000 BTUs). It activates each time you open the cylinder valve, so be sure the
appliance is turned OFF before you open the valve. If the appliance is not turned OFF when
you open the valve, the Flow Limiting Device will not be able to reset and will restrict gas
flow to the appliance.