REPLACING THE TRIMMING LINE
Refer to the Line Replacement Addendum for complete instructions.
MAINTAINING THE AIR FILTER
Failure to maintain the air lter can result in poor performance or can cause permanent damage to the
engine. Engine failure due to improper air lter maintenance is not covered by the product warranty.
Cleaning the Air Filter
1. Open the air lter cover by unscrewing the cover screw (Fig. 19).
2. Remove the air lter from the air lter housing (Fig. 19).
3. Wash the air lter in detergent and water. Rinse the air lter thoroughly and allow it to dry.
4. Lightly coat the air lter with clean SAE 30 oil.
5. Squeeze the air lter to spread and remove excess oil.
6. Reinstall the air lter in the air lter housing (Fig. 19).
NOTE: Operating the unit without the air lter and air lter cover will VOID the warranty.
7. Insert the hooks on the air lter housing into the slots on the air lter cover (Fig. 20).
8. Swing the air lter cover to the right and align the cover screw with the cover screw hole (Fig. 20).
Tighten the cover screw to secure the air lter cover.
NOTE: Do not over tighten as this may strip the screw.
Fig. 19
Air Filter
Air Filter
Housing
Air Filter Cover
Cover Screw