FIGURE 38
Transmitter
“RE Models
1. Turn Valve Knob to “ON” position (Figure 35A) then slide switch on the Receiver (Figure 36) to “REMOTE” position.
2. Depress the “ON/HI” button on the TRANSMITTER (Figure 37) until a click is heard. The burner will then light to “Full
on”.
NOTE: Reducing the burner flame can be achieved by pressing the “LO” button one beep at a time to the desired flame
height. Pressing the “ON/HI” button one beep at a time will raise the burner flame). To verify the burner is com-
pletely off, press the “OFF” button once.
PILOT FLAME ADJUSTMENT: If adjustment is necessary, use a narrow long stem screw driver to turn pilot adjustment
screw. To adjust turn clockwise for less pilot flame, counterclockwise for more pilot flame.
IMPORTANT SERVICE TIP! Obstructed Pilot Air Intake Ports result in an improper gas/air mixture and a weak pilot
flame. Weak pilot flame is the NUMBER 1 SERVICE ISSUE REGARDING NUISANCE SHUT-OFF. Using canned
compressed air, a pipe cleaner or an artist's brush, clean out the opposing air intake ports located at the base of the pilot
(where the gas supply line attaches to the pilot) (See page 13, Figures 23A and B).
STEP TWO: PILOT ADJUSTMENT (ALL MODELS)
STEP THREE: BURNER OPERATION (“RE” VARIABLE FLAME HEIGHT MODELS AND“SE” REMOTE READY)
FIGURE 39
FIGURE 37
Slide Switch in “REMOTE” Position
Wireless On/Off
Remote with
Thermostat
(THR-2R)
Wireless Wall
Thermostat
(TS-2R)
Accessory Controls
Wireless Wall Timer
(30/60/120 Minutes)
(WT-2R)
Wireless On/Off
Remote
(SR-2R)
Wireless Wall
Switch
(WS-2R)
FIGURE 36
NOTE: The “EASY” Safety Valve has complete control of gas to the pilot and burner. It cannot be turned to “OFF”
without first depressing knob to the “PILOT” position and then rotating clockwise to “OFF”.
B) Pilot Adjustment
Screw
A) “EASY” Safety Valve
Knob
C) Knob Position Indicator
B) Pilot Adjustment
Screw
A) “EASY” Safety Valve
Knob
C) Knob Position Indicator
DC Variable Motor drive
“SE” Models
1. Turn Valve Knob to “ON” position (Figure 38A below right) then slide switch on the Receiver (Figure 36 above) to
“REMOTE” position.
2. Consult Operating Instructions for Accessory Control (below), then adjust the burner flame height by turning the Valve
Knob (Figure 38A) clockwise to lower and counter-clockwise to raise up to full on.
NOTE: During the heating season leave Valve Knob in “PILOT” position for convenience. Otherwise, turn to “OFF”
position for any prolonged non-use.