Loading ...
Loading ...
Loading ...
GROUNDING INSTRUCTIONS
This appliance must be grounded.
In the event of malfunction or break-
down, grounding will reduce the risk
of electric shock by providing a path of
least resistance for electric current. The
power supply cord must be plugged into
an appropriate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
WARNING: Improper connection of the
equipment-grounding conductor can
result in a risk of electric shock. Check
with a qualified electrician or serviceman
if you are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug on the power
supply cord. If it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
STEP 1. Disconnect power.
STEP 2. Remove hold-down screw
and terminal block cover.
H01d-d0wnscrew
STEP 3. Attach a 3/4-inch, U.L.-listed
strain relief to the hole below terminal
block opening. Strain relief should have
a tight fit with dryer cabinet and be in a
horizontal position. Put the power supply
cord through the strain relief.
STEP 4. Remove the center terminal
block screw. Remove the neutral ground-
ing wire (green/yellow wire) from external
grounding screw.
External ground
connector
Green/yellow wire
of harness
Centersilver-colored
terminalblockscrew
J
Terminalblockcover
19
Loading ...
Loading ...
Loading ...