Loading ...
Loading ...
Loading ...
RECESSED AREA/CLOSET
iNSTALLATiON iNSTRUCTiONS
Check governing codes and ordinances.
This dryer may be installed in a recessed
area or closet.
The dryer must not be installed where it
can be exposed to water and/or weather.
* Proper operation of dryer cycles
requires temperatures above 45°F (at
lower temperatures, the dryer may not
shut off at the end of automatic cycles
and drying times will be extended).
* Check code requirements. Some
codes limit or do not permit installation
of clothes dryers in garages, closets,
mobile homes, or sleeping quarters.
Contact your local building inspector.
WARNING: To reduce the risk of fire, this
appliance must be exhausted outdoors.
NOTE: No fuel-burning appliances may
be installed in the same closet as a dryer.
MINIMUM INSTALLATION SPACING
I 29"-H F-.1,,
FrontView SideView
(DoorNotShown) (Door Shown)
**a.8.sq. in:_
r,,lIfll I_ nil}
ventilation
area
**24 sq. in.
minimum
ventilatien
area
_J:
3"
f
3"
FrontView
(Door WithVent)
* Additionalclearancesfor wall, doorandfloor moldings mayherequired. 0" clearance
isacceptablehntnotrecornmended.
** Openingisminirnnmforclosetdoor.Lonvereddoorwithequivalentair
openingsisacceptable.
*** Additionalspaceisneededwhenexternalexhaustelbow isused.Canbe0" clearance
whenhouseexhaustingislinedupdirectly withdryerexhaust.
* In the above illustration, the installation
spacing is in inches and is the minimum
allowable.
* Additional spacing should be considered
for ease of installation and servicing.
* If closet door is installed, the minimum
air openings in top and bottom are
required. Louvered doors with equivalent
air openings in top and bottom are
acceptable.
* All installations must be exhausted
outside. Use at least the minimum
dimensions indicated.
I0
Loading ...
Loading ...
Loading ...