8 www.dimplex.com
Site Selection
Review and consider all of the
following conditions before instal-
lation:
Dimensions of the unit: 34.1 in.
(867 mm) x 19.4 in. (494 mm)
Unit requires a minimum of two
wall studs in order to ensure a
secure installation
There are three possible mount-
ing methods:
Surface mount (pg. 11);
In-wall Recessed (pg. 13);
Flush mount (pg. 14),
and any of these have the option
of being hard-wired or plugged
directly into the wall outlet.
!
NOTE: If the desired replace
location is on an exterior wall the
unit should only be surface mount-
ed. If a in-wall or ush mount look
is desired build the interior wall
out into the room.
!
NOTE 1: A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not essen-
tial in all cases. A dedicated circuit
will be required if, after installa-
tion, the circuit breaker trips or
fuse blows on a regular basis
when the heater is operating. Ad-
ditional appliances on the same
Fireplace Installation
circuit may exceed the current
rating of the circuit breaker.
WARNING: Ensure the power
cord is not installed so that it
is pinched or against a sharp
edge and ensure that the
power cord is stored or secured
to avoid tripping or snagging to
reduce the risk of re, electric
shock or injury to persons.
Construction and electrical
outlet wiring must comply
with local building codes and
other applicable regulations to
reduce the risk of re, electric
shock and injury to persons.
WARNING: To reduce the risk
of re, do not store or use gaso-
line or other ammable vapors or
liquids in the vicinity of the heater.
1. Select a location that is not
susceptible to moisture and
is away from drapes, furniture
and high trafc.
2. For ease of electrical hook
up you may wish to locate
the replace near an existing
outlet (for plug-in convenience)
(refer to NOTE 1).
3. Remove replace, front glass
and hardware from the box
and remove all packaging ma-
terials before installation.