10 www.dimplex.com
Fireplace Installation
the service panel until installa-
tion is complete.
1. Carefully remove the electrical
cord bracket from the back of
the replace by removing the
three retaining screws.
(Figure 2)
2. Remove the two wire access
covers off of the unit at the
front to access the wire con-
nections. (Figure 3)
3. Pull the wires and connectors
out of the back opening.
4. Unscrew the two wire connec-
tors inside the electrical box
and separate the wires.
5. Install the supplied hardwire
bracket (with the ½" wire hole)
onto the rebox. (Figure 2)
6. Leaving a minimum of 3 in.
(7.6 cm) of slack, route the
power supply wires through
the hole in the electrical cover
bracket and secure with a wire
clamp (not supplied).
7. Connect the black wire (L)
from the unit to the live wire
from the power supply using
one of the wire connectors
removed in step 4.
8. Connect the white wire (N)
from the unit to the neutral
Figure 6