CONNECTIONS PLUMBING
31
LEFT AND RIGHT HAND SIDE WATER CONNECTIONS
The cold and hot water supplies (050 to 400 models) and temperature pressure
relief valve (050 to 125 models) can be connected to either side of a water
heater with both left and right hand side connections. A kit is supplied with the
water heater to plug off the unused cold water and hot water fittings, and where
applicable the unused temperature pressure relief valve fitting.
The kit contains:
Models 050 to 125
Models 160 to 400
2 x ¾” brass plugs
2 x ¾” brass plugs
1 x ½” brass plug
2 x plastic caps (991/992160 models)
3 x plastic caps (050 models)
2 x insulation rubber discs,
3 x insulation rubber discs,
pre-fitted into plastic caps (050 models)
pre-fitted into plastic caps
(991/992160 models)
1 x allen key
1 x allen key
Plugging Off Unused Connections
Apply approved sealing tape or compound to the thread of each plug.
Fit the ¾” plugs to the unused cold water fitting and unused hot water fitting.
Tighten the plugs with the allen key supplied.
Fit the ½” plug to the unused TPR valve fitting (050 to 125 models). Tighten
the plug with the allen key supplied.
Fit a plastic cap (where supplied) with its insulation rubber disc over each
plug.
SK7232
Rev. BD 3/13
INSULATION CAP & DISK ASSEMBLY
BRASS PLUG
INSULATION RUBBER
PLASTIC CAP
SK7396
REV AD 02/13
INSULATION CAP & DISK ASSEMBLY
080-400 MODELS ELECTRIC
TPRV FITTING
080 & 125
MODELS ONLY
BRASS PLUG
INSULATION RUBBER
PLASTIC CAP
050 models 080 to 400 models