Rheem 991315G7 Aquamax 315L 3.6KW Dual Hand Electric Hot Water System

User Manual - Page 11

For 991315G7.

PDF File Manual, 44 pages, Read Online | Download pdf file

991315G7 photo
Loading ...
Loading ...
Loading ...
MAINTENANCE REQUIREMENTS
11
MINOR MAINTENANCE EVERY SIX MONTHS
It is recommended minor maintenance be performed every six (6) months.
Minor maintenance can be performed by the dwelling occupant.
The minor maintenance includes:
Operate the easing lever on the temperature pressure relief valve. It is very
important you raise and lower the lever gently. Refer to “Temperature
Pressure Relief Valve” on page 12.
Warning: Exercise care to avoid any splashing of water, as water
discharged from the drain line will be hot. Stand clear of the drain line’s
point of discharge when operating the valve’s lever.
Operate the easing lever on the expansion control valve (if fitted). It is very
important you raise and lower the lever gently. Refer to “Expansion Control
Valve” on page 11.
Check the drain line from the safe tray (if one is installed) is not blocked.
EXPANSION CONTROL VALVE
In many areas, including South Australia, Western Australia and scaling water
areas, it is mandatory an expansion control valve is fitted to the cold water line
to the water heater. The expansion control valve may discharge a small
quantity of water from its drain line during the heating period instead of the
temperature pressure relief valve on the water heater.
Operate the easing lever on the expansion control valve once every six
months. Refer to “Minor Maintenance Every Six Months on page 11. It is very
important the lever is raised and lowered gently. If water does not flow
freely from the drain line when the lever is lifted, then the water heater should
be checked by Aquamax Service. The expansion control valve should be
checked for performance or replaced at intervals not exceeding five (5) years,
or more frequently in areas where there is a high incidence of water deposits.