22 49-5000355 Rev. 6
INSTALLATION INSTRUCTIONS
Installation Instructions
1. INSTALL THE WALL
SLEEVE AND EXTERIOR
GRILLE
7KH5$%%VHULHVRU5$%ZDOOVOHHYHPXVW
be properly installed per instructions packed with the
sleeve.
Assembly the wall sleeve as detailed in the
instructions packed with it. Ensure all pieces are
properly snapped together.
Attach the outdoor panel to the rear of the
assembly to help close off the building from the
elements.
,QVWDOOVHFXUHDQGFDXONWKHVOHHYH
When the chassis is ready to be installed, remove
the outdoor panel and then install and secure the
grille prior to installing the chassis.
,QVWDOOWKHH[WHULRUJULOOHIURPWKHURRPVLGHIROORZLQJ
instructions packed with the grille.
NOTE: For installation with a subbase or duct adapter,
see the instructions packed with those kits.
2. PREPARE THE UNIT
Carefully remove the foam shipping blocks from
WKHURRPIURQWFRPSUHVVRUDQGRXWGRRUIDQ7KHUH
may be multiple blocks and pieces of shipping tape
that need to be removed.
Remove the room cover by pulling it out at the
ERWWRPWRUHOHDVHLWWKHQOLIWLWXSWRFOHDUWKHUDLO
DORQJWKHXQLWWRS
,IYHQWGRRULVWREHRSHUDWLRQDOUHPRYHVKLSSLQJ
screws from the front side of the vent door, if
present.
INSTALLING THE ZONELINE
Shipping tape
/RFDWLRQVPD\YDU\
Remove the
shipping screws
(if operation is
GHVLUHG
Loading ...
Loading ...