GE Zoneline AZ65H12DABW2 Heat Pump Unit

OWNER’S MANUAL - Page 19

For AZ65H12DABW2. Also, The document are for others GE - General Electric models: AZ45, AZ65

PDF File Manual, 90 pages, Read Online | Download pdf file

AZ65H12DABW2 photo
Loading ...
Loading ...
Loading ...
49-5000355 Rev. 6 
Installation Instructions
INSTALLATION INSTRUCTIONS
Power cords may include an arc fault interruption
or a leakage current detection interruption device.
A test and reset button is provided on the plug
case or the inline case. The device should be
tested on a periodic basis by first pressing the
TEST button and then the RESET button. If the
TEST button does not trip or if the RESET button
will not stay engaged, discontinue use of
the Zoneline and contact a qualified service
technician.
POWER CORD
CONNECTION
'HSHQGLQJRQDSSOLFDWLRQDSRZHUVXSSO\NLWZLWK/&',
PXVWEHXVHGWRVXSSO\SRZHUWRWKH=RQHOLQHXQLW7KH
appropriate kit is determined by the voltage, the means
of electrical connection and the amperage of the branch
circuit.
&RQQHFWLRQVRIRUYROWFLUFXLWVPD\EHZLWKD
SRZHUVXSSO\NLWRUDMXQFWLRQER[NLW
All wiring, including installation of the receptacle,
must be in accordance with the NEC and local codes,
ordinances and regulations. Codes require the use of
an arc fault or leakage current detection device on the
SRZHUFRUGH[FHSWGLUHFWFRQQHFW%HVXUHWRVHOHFW
the correct cord for your installation.
230/208 VOLT ELECTRICAL CONNECTION OPTIONS
DIRECT CONNECTION
2UGHURQHRIWKHIROORZLQJ.LWVIRUYROWGLUHFW
FRQQHFWLRQDVUHTXLUHG
Review installation instructions provided with direct
connect kits for detailed assembly instructions.
When using a direct connection, the RAK4002D
Junction Box is required for a complete and proper
installation.
Tandem
$PS
YROWUHFHSWDFOHFRQILJXUDWLRQ
Perpendicular
$PS
Large
Tandem
$PS
Power supply kit
($SSHDUDQFHPD\YDU\
ELECTRICAL SUBBASE
CONNECTION
YROWPRGHOVPD\EHLQVWDOOHGXVLQJRQHRIWKH
IROORZLQJHOHFWULFDOVXEEDVHV
Electrical subbases provide an enclosure for direct
FRQQHFWLRQRUHQFORVHGUHFHSWDFOHV7KHVXEEDVHNLW
includes the power cord.
7KHLQVWUXFWLRQVSURYLGHGZLWKWKHVHOHFWHGVXEEDVH
NLWPXVWEHFDUHIXOO\IROORZHG,WLVWKHUHVSRQVLELOLW\RI
the installer to ensure the connection of components
is done in accordance with these instructions and all
electrical codes.
When using a sub-base electrical connection, the
RAK4002D Junction Box is required for a complete
and proper installation.
Branch Circuit and
Unit Amperage Rating
Proper GE Appliances
Power Cord
with LCDI Device
 5$.3
 5$.3
 5$.3
Branch Circuit and
Unit Amperage Rating
Proper GE Appliances
Subbase Kit
 5$.'&
 5$.'&
 5$.'&
Branch Circuit and
Unit Amperage Rating
Power Supply Kit
 5$.'
 5$.'
 5$.'
Loading ...
Loading ...
Loading ...