Rheem RTG84DVLP1 Tankless Gas Mid-Efficiency - 180kBTU/HR

USE AND CARE MANUAL - Page 65

For RTG84DVLP1.

PDF File Manual, 80 pages, Read Online | Download pdf file

RTG84DVLP1 photo
Loading ...
Loading ...
Loading ...
65
The factory setting for this switch should all be in
the OFF position (DOWN).
Change the first switch on “DIP 2” to the ON
position (UP). Performance mode is selected.
To select Energy Saver mode, change the fourth
switch on “DIP 1” to the ON position (UP).
Replace the front cover panel.
Turn on all electric power to the water heater.
Turn On the remote control. The pump and water
heater will turn on to raise recirculation loop
temperature.
Recirculation Operation
The water heater is turned ON when the
recirculation pump starts operation. The water
heater produces hot water at the setting
temperature. When the return water temperature
reaches approximately 15°F below the setting
temperature, the water heater and the pump will
turn OFF. The cycle will restart at the approximate
time interval in the table below based on the
temperature thermistor readings.
Energy Saver Mode
The Energy Saver mode operates as follows:
Less energy consumption due to fewer pump
cycles
• Pump cycles ON every 30 to 69 minutes
Performance Mode
The Performance mode operates as follows:
Higher energy consumption due to more pump
cycles
• Pump cycles ON every 15 to 35 minutes
Setting Temp Typical Pump ON Intervals [Min]
[°F] Performance Energy Saver
140 15 30
135 15 30
130 15 30
125 15 30
120 16 31
118 17 33
116 18 35
114 19 38
112 20 40
110 22 44
108 24 47
106 26 51
104 28 56
102 31 62
100 35 69
Actual pump ON intervals may vary based on the
setting temperature, insulation, and heat loss in the
system.
INSTALLATION INSTRUCTIONS
10
9
11
12
8
As set
from factory
MIN MAX ADJ
Recirculating Pump