9
120V MAIN POWER WALL SWITCH
FIREPLACE JUNCTION BOX
120 V
POWER
SUPPLY
(BREAKER
PANEL)
WHITE - N
RED L2
BLACK L1
WHITE – N
BLACK L1
GROUND - G
WALL
SWITCH
GROUND - G
!
NOTE: This option should not be used with the remote control kit.
!
NOTE: Before installing the unit have the following wires installed:
1. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.
2. A 2 conductor wire with ground (3 wires total) from the main switch wall box to the junction box on the unit.
!
NOTE: Use a single pole, single throw (On/Off) wall switch that is rated for a minimum of 15 amps.
1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Ensure that the
switch is in the 120V position. (115 is printed on switch)
2. Loosen the screw securing the junction box cover and remove the cover.
3. Remove the knockouts (if necessary) or use the provided cable clamp.
4. Pull out the four wires marked L1, L2, N, and G (black, red, white and green).
5. Connect L1 (black) from the unit to the L1 (black) from the main power wall switch using a wire connector (not supplied).
6. Connect the other end of L1 (black) to the L1 terminal of the main power wall switch.
7. Connect L2 (red) from the unit and N (white) from the unit to the Neutral wire (white) of the main power wall switch by us-
ing a wire connector (not supplied).
8. Connect the other end of the N (white) to the Neutral wire (white) from the power supply panel by using a wire connector
(not supplied).
9. Connect Ground (green) from the unit to the Ground (green) wire of the main power wall switch by using a wire connector
(not supplied).
10. Connect L1 (black) wire from the power supply to the L1 terminal of the main power wall switch.
11. Secure the 2 remaining Ground wires (green) with a ground screw in the main switch wall box.
12. Ensure that all connections are tight.
13. Insert all the wiring of the main power wall switch into the main switch wall box.
14. Insert all the wiring back into the unit and secure with a cable clamp.
FROM MAIN SWITCH
2 CONDUCTOR WIRE
FROM POWER SUPPLY
2 CONDUCTOR WIRE
L2
N
L1
G
L1 FROM UNIT
G FROM
POWER SUPPLY
G FROM UNIT
L1 FROM
POWER SUPPLY
NEUTRAL FROM
UNIT AND SUPPLY
UNIT AND SUPPLY
NEUTRAL FROM
POWER SUPPLY
L1 FROM
G FROM UNIT
POWER SUPPLY
G FROM
L1 FROM UNIT
G
L1
N
L2