User Manual - Page 6

For BF39DXP. Also, The document are for others Dimplex models: BF33STP/DXP, BF39STP/DXP, BF45DXP

Loading ...
Loading ...
Loading ...
6
www.dimplex.com
!
IMPORTANT: The unit is factory congured for 208/240V operation.
!
NOTE: Use 3 conductor wires with ground (4 wires total) from the power supply (breaker panel) to the junction box on the
unit.
!
NOTE: All wiring must be completed prior to installing the unit.
!
NOTE: Ensure that the voltage selector switch is in the proper position for the required supply voltage prior to connecting
the unit to the power supply.
1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Ensure that the
switch is in the 240V position. (230 is printed on switch)
2. Loosen the screw securing the junction box cover and remove the cover.
3. Remove the knockouts (if necessary) or use the provided cable clamp.
4. Pull out the four wires marked L1, L2, N, and G.
5. Connect L1 (black) from the unit to the L1 (black) from the power supply.
6. Connect L2 (red) from the unit to the L2 (red) from the power supply.
7. Connect N (white) from the unit to the to the Neutral (white) from the power supply.
8. Connect the ground wire (green) from the unit to the ground from the power supply.
9. Ensure that all connections are tight.
10. Insert all the wiring back into the unit and secure with a cable clamp.
240 V
POWER
SUPPLY
(BREAKER
PANEL)
FIREPLACE JUNCTION BOX
WHITE WIRE - N
RED WIRE L2
BLACK WIRE L1
GREEN WIRE - G
WHITE WIRE - N
RED WIRE L2
BLACK WIRE L1
GROUND WIRE - G
SECTION C: DIRECT POWER WIRING
240V INSTALLATION
!
IMPORTANT: The unit is factory congured for 208/240V operation.
!
NOTE: Use 2 conductor wires with ground (3 wires total) from the power supply (breaker panel) to the junction box on the
unit.
!
NOTE: All wiring must be completed prior to installing the unit.
!
NOTE: Ensure that the voltage selector switch is in the proper position for the required supply voltage prior to connecting
the unit to the power supply.
1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Flip the switch from
240V to 120V conguration. (230 and 115 is printed on switch)
2. Loosen the screw securing the junction box cover and remove the cover.
FIREPLACE JUNCTION BOX
120 V
POWER
SUPPLY
(BREAKER
PANEL)
WHITE WIRE - N
RED WIRE L2
BLACK WIRE L1
WHITE WIRE - N
BLACK WIRE L1
GROUND WIRE - G
GREEN WIRE - G
120V INSTALLATION
Loading ...
Loading ...