49-6000065
Specifications
SPECIFICATIONS: Performance Data
Performance Data
GE Appliances Reverse Osmosis System
Model(s): PNRQ15RBL, and PXRQ15RBL
Use Replacement Cartridge(s): FQROPF (pre and post filter)
and FQROMF (membrane filter)
The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system as specified in NSF/
ANSI Standard 42, Standard 58 and CSA B483.1.
System tested and certified by NSF
International against NSF/ANSI to Standard 42,
Standard 58 and CSA B483.1 for the reduction
of substances as listed below.
Capacity 11.15 gpd (gallons per day) 42.2 lpd (liters per day). Contaminant Reduction Determined by NSF testing.
Substance Reduction
Average
Influent
NSF specified
Challenge
Concentration
Avg %
Reduction
Average
Product Water
Concentration
Max Permissible
Product Water
Concentration
NSF Reduction
Requirements
NSF Test
Report
Chlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10%  0.05 mg/L N/A  -
Nominal Particulate
&ODVV,,,WRP
70,333 pts/
mL
At least 10,000 particles/
mL
 23 pts/mL N/A  -
Arsenic (pentavlent) 0.032 mg/L 0.050 mg/L ± 10%  PJ/ 0.010 mg/L N/A J-00122054
Asbestos 
fibers/L
10
7
to 10
8
fibers/L; fibers
JUHDWHUWKDQP
 < 1 fiber/L NA  -
Barium PJ/ 10 mg/L
± 10%
 0.310 mg/L 2.00 mg/L N/A J-00122055
Cadmium 0.028 mg/L 0.03 mg/L ± 10%  0.0003 mg/L 0.005 mg/L N/A -
Chromium (Hex.) 0.28 mg/L 0.3 mg/L ± 10% (added
as hexavalent)
 0.008 mg/l 0.1 mg/L N/A J-00122054
Chromium (Tri.) 0.32 mg/L 0.3 mg/L ± 10% (added
as triavalent)
 0.01 mg/l 0.1 mg/L N/A J-00122055
Copper PJ/ 3.0 mg/L + 10%  0.027 mg/L 1.3 mg/L N/A -
Cyst 140,000
cysts/L
Minimum 50,000 cysts/L  3 cyst/L N/A  -
Lead 0.14 mg/L 0.15 mg/L + 10%  0.001 mg/L 0.010 mg/L N/A -
5DGLXP 25 pCi/L 25 pCi/L ± 10% 80.0% 5 pCi/L 5 pCi/L N/A J-00122055
Selenium 0.1 mg/L 0.10 mg/L ± 10% (added
as ½ selenite and ½
selenate)
 0.002 mg/L 0.05 mg/L N/A J-00122057
TDS PJ/ 750 mg/L + 40 mg/L  42 mg/L 187 mg/L N/A -
Turbidity 11 NTU 11 ± 1 NTU  0.1 NTU 0.5 NTU N/A -
Operating Specifications
Inlet Pressure 40-120 psig (2.8-7.0 kg/cm
2
)
Inlet Temperature
40-100 F° (5-38° C)
Maximum TDS Level 2000 mg/L
Maximum Hardness @ 6.9pH 10 grains per gal. (171 mg/L)
Maximum Chlorine 2.0 mg/L
pH Range 4 – 10
Daily Production Rate 8.46 GPD (32.0 L/day)
Efficiency Rating
(3)
9.05%
Recovery Rating
(4)
19.84%
Notes:
(1) Tested by NSF International per NSF/ANSI Standard 58 or NSF/ANSI Standard 42.
(2) NTU is Nephelometric Turbidity Units
(3) Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis
treated water under operating conditions that approximate
typical daily usage.
(4) Recovery rating means the percentage of influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is