Loading ...
Loading ...
Loading ...
Converting Type 2 Pressure Regulator for Use with
LP/Propane
1. Remove pressure regulator capwith a wrench.
2. Reverse pressure regulator cap.
• Cap must show"LP'.
3. Place pressure regulator cap on pressure regulator
and tighten.
Ca
4. While facing range front, turn orifice hoods
counterclockwise 1½ to 2 turns or until snug.
• Use ½ inch open end or 90° offset open end
wrench.
• Do not over tighten orifice hoods. If orifice hoods are
over tightened, gas supply can be cutoffor orifice
hoods can strip.
5. Open airshutterfully.
A
Open Fully
Type 2 Pressure Regulator
Converting Surface Burners for Use with LP\Propane
1. Remove 4 burner control knobs from range.
• Exposes 2 screws on burner control panel.
2. Remove 2 screws from burner control panel.
• Panel drops slightly after screws are removed.
3. Grasp bottom of burner control panel, gently lift and
pull out panel until clear of burner valve stems.
• After burner control panel clears valve stems,
continue to roll panel until free from range. Set
aside. See Pivot Point in figure.
• Gas valve and orifice hood are visible after burner
control panel is removed.
.
A Orifice Hood
B_ir Shutter
Converting Surface Burners for Use with LP Propane
Reassemble burner control panel after adjusting air
shutter.
• See Adjusting Surface Burner Flame section.
A
_Bumer Control Knob
B Pivot Point
C Burner Control Panel
D Screw
Burner Control Panel
Loading ...
Loading ...
Loading ...