7
In compliance with local codes, install an electrical junction
box near the hood’s electrical access holes.
1. In the cabinet or wall, drill 7/8” holes through which to
pass the electrical wiring.
2. See the last pages of this guide for wiring diagrams.
Suggested Area of Junction Box
Preparation and Setup
Installing the Electrical Source
See the diagram below: Top/Rear Electrical Access
Holes for wire hole locations inside the hood.
See Wiring Diagrams at the end of this document.
Hood
Junction Box Area
Top/Rear Electrical Access Holes
The hood must be at least as wide as the cooktop.
All dimensions must meet or fall within the specified mini-
mums.
Dimensions given are minimum clearances unless other-
wise noted.
All contact surfaces between the hood and cabinetry/
walls must be sturdy, solid, and at right angles.
Install the hood and cooking appliance(s) so they can be
removed for service.
IMPORTANT
See the diagram for minimum installed distance from
the hood to the cooktop surface. The minimum specified
distance may be higher for the particular range or
cooktop in use. Check the manufacturers specifications
for the cooktop or range.
Meeting Installation Requirements
WARNING
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for details. Use only ductwork accepted by
state, municipal, and local codes.
To reduce risk of injury from reaching over a hot
appliance, do not place cabinets directly over the range.