aXis CONTROLLER HOME STANDBY GENERATOR
INSTALLATION
36
Be careful to avoid corrosion on the battery post(s). Corrosion
can have the effect of creating an insulation between the post(s)
and the cable(s), this will severely affect the performance of the
battery. Follow battery manufacturers’ instructions on proper
maintenance, service or replacement. The correct wire lands are
read left to right, 6 land points;
Wire Land
Points
Function Wire Color
Wire land #1 Ground G (green)
Wire land #2 L1 P (pink)
Wire land #3 N W (white)
Wire land #4 Not Connected- Empty
Wire land #5 B- B (black)
Wire land #6 B+ R (red)
A 120VAC circuit must be installed for battery charging. From ATS
fuse block or distribution panel install L1 and N to Wire land # 2
and #3 respectively.
Automatic Transfer Switch (ATS)
The most reliable and convenient method to transfer power is with
an automatic transfer switch (ATS). The ATS will automatically
disconnect the home from the utility power prior to the HSB
functioning (see NEC 700, 701 and 702). Failure to disconnect the
home from the utility with an approved UL listed ATS can result
in damage to the HSB and can also cause injury or death to utility
power workers who may receive electrical back-feed from the
HSB.
ATS includes sensors to detect when a power failure (utility lost)
occurs. These sensors trigger the ATS to disengage the home from
the utility power. When the HSB reaches the proper voltage and
frequency, the ATS will automatically transfer generator power to
the home.
The ATS module continues to monitor the utility source for the
return of utility power. When the utility power returns, the ATS
disengages the home from generator power and re-transfers the
home to utility power. The HSB is now off line and will shut down-
returning to the standby mode.
NEMA 3R – This type of enclosed ATS is similar to the indoor box,
except that it is a weatherproof enclosure and required for exterior
installations by code. The enclosure has knockouts on the bottom
and side, and requires water tight connections when installed
outside per code. This enclosure can also be used inside.
aXis Controller™ Module
This standby generator is designed to communicate with the ATS
using the integrated aXis Controller™ module. In order to utilize
features such as load management, wifi programming, wireless
exercise programming, etc., it is necessary that the ATS contains
aXis Controller™ electronics.
While it is possible to connect this standby generator to a non-aXis
Controller™ ATS using the two-wire connection shown in this
manual, it will reduce the functionality of the standby generator
significantly. If the standby generator is being controlled with
the two-wire connection, the standby generator will turn on and
off based on the two-wire signal. Full power will still be provided
through the circuit breaker however wifi connectivity and the
exterior fault code indicator will lose functionality.
ATS Installation
Refer to the ATS instruction guide enclosed with each ATS
for information related to the installation, operation, service,
troubleshooting, and warranty.
After Performing Installation of Champion ATS with aXis
Controller™ Module, complete the following steps to finish the
installation of this standby generator.
OTE: N If a non-aXis Controller™ ATS was installed, please skip
to section “Installing Standby Generator to non-aXis
Controller™ ATS” on page 40 to finish installation.
FULL SYSTEM CHECK
1. Open Utility breaker for full system test, close breaker after
confirming all systems working.
2. After Utility breaker opens engine will start automatically.
3. aXis ATS control panel will reboot on Generator power and
control switching of latching relays.
4. Home is now powered by Generator. If Load Management
modules (LMM) have been installed, please allow 5 minutes
for LMM and AC1/AC2 to become active.
5. Perform Load Learning through ATS panel at this time. LMM
units will be dropped and reacquired in order.
6. Close Utility breaker
7. System is now fully functional.
Loading ...
Loading ...
Loading ...